WSL-150-12/24
Parameter
Input voltage:220Vac
Output power:150W
Output voltage:12Vdc/24Vdc
Feature
1. Protection: short-circuit, overload
2. 100% full-load aged
3. Withstand 300VAC surge input for 5 seconds
4. -20~+60℃Working temperature
5. 5G vibration tested
6. High efficiency, long life span, and high reliability
Applications: Industrial automation machinery、Industrial control system、Testing and measuring instruments、Household appliances、
Led lighting appliances、Aging equipment、IT communication equipment
Warranty
2 years
Certificate
CE RoHS
| Product No. | WSL-150-12 | WSL-150-24 | ||||
| Output | DC voltage | 12V | 24V | |||
| Rated Current | 12.5A | 6.3A | ||||
| Current Range | 0-12.5A | 0-6.3A | ||||
| Rated Power | 150W | 150W | ||||
| Ripple and Noise(Max)Note.2 | 150mVp-p | 240mVp-p | ||||
| Voltage adjustment | 10.8-13.2V | 22-27.6V | ||||
| Voltage tolerance Note3 | ±1% | ±1% | ||||
| Linear Regulation Note4 | ±0.5% | ±0.5% | ||||
| LoadRegulationNote5 | ±0.5% | ±0.5% | ||||
| Setup and rise time | 1000ms,30ms/230VAC 1000ms,30ms/110V | |||||
| Hold up time(Typ) | 50ms/230VAC10ms/115AC | |||||
| Input | Voltage range | AC 220±15% | ||||
| Frequency range | 50HZ/60HZ | |||||
| Efficiency(Typ) | 80% | 81% | ||||
| AC current(Typ) | 2.8A/110V1.4A/220V | |||||
| Surge (Inrush) current (Typ) | Cold start:65A/230VAC | |||||
| Leakage Current | <2mA/240VAC | |||||
| Protection | Overload | >105% rated output power | ||||
| Protection type:Hiccup mode, recovers automatically after fault condition is removed | ||||||
| Over temperature | Overheat protection starts when temperature in transistor over 140℃ | |||||
| Recovers automatically after temperature is normal. | ||||||
| Environment | Working temp. | -20~+60℃ | ||||
| Working humidity | 20~90% RH,Non-condensing | |||||
| Storage temp & hmdty | -40~+80℃ | |||||
| Temp. coefficient | ±0.03%/℃ (0~50℃) | |||||
| Vibration proof | 10~500HZ,5G 10min/1 cycle,period for 60min. each along X、Y、Z axes | |||||
| Safety reg. & EMC(Note.6) | Safety regulation | GB195110.1-2004/IEC61347-1:2003CE(EMC+LVD) | ||||
| Voltage proof | I/P-O:3.75KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC | |||||
| Isolation resistance | I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/70% RH | |||||
| EMC irradiation | EN 55015:2006;EN61000-3-2:1995+A2:2005 | |||||
| EMC disturbance proof | EN 61000-3-2:2006; | |||||
| Others | Dimensions | 254*58*26(L*W*H) | ||||
| Packing | 0.632kg/PCS;30PCS/20kg | |||||
| Remark | 1. Unless specially indicated, all data are taken under 230VAC input, rated load and 25℃environment temp. | |||||
| 2.Ripple and noise: measured with a 12” double ripple cord connected in parallel with a 0.1μF and a 47 μF capacitor on 20MHz bandwidth. | ||||||
| 3.Tolerance(Accuracy): including preset errors, linear adjustment rate and load adjustment rate. | ||||||
| 4.Linear adjustment: taken under rated load from low voltage to high voltage. | ||||||
| 5.Load adjustment: taken under 0~100% of rated load. | ||||||
| 6. Power supply is taken as part of the whole system, and needs to be confirmed with terminal instruments for EMC. | ||||||