Parameter
Input voltage:176-264Vac
Output power:250W
Output voltage:12Vdc/24Vdc
Feature
1. Protection: short-circuit, overload
2. 100% full-load aged
3. Withstand 300VAC surge input for 5 seconds
4. -20~+60℃Working temperature
5. Dimmable power supply
6. High efficiency, long life span, and high reliability
Applications: Led lighting appliances
Warranty
3 years
Certificate
CE RoHS
| Product No. | DM-250-12 | DM-250-24 | |
| Output | DC voltage | 12V | 24V |
| Rated Current | 20A | 10A | |
| Current Range | 0-20A | 0-10A | |
| Rated Power | 250W | 250W | |
| Ripple and Noise(Max)Note.2 | 150mVp-p | 240mVp-p | |
| Voltage adjustment | 10.8-13.2V | 22-27.6V | |
| Voltage AccuracyNote3 | ±1% | ±1% | |
| Linear Adjustment Note4 | ±0.5% | ±0.5% | |
| Load AdjustmentNote5 | ±0.5% | ±0.5% | |
| Start and rise time | 1000ms,30ms/230VAC 1000ms,30ms/110V | ||
| Hold time(Typ) | 50ms/230VAC10ms/115AC | ||
| Input | Voltage range | AC 176-264V | |
| Frequency range | 50HZ/60HZ | ||
| Efficiency(Typ) | 80% | 82% | |
| AC current(Typ) | 3.7A/110V1.8A/220V | ||
| Surge current (Typ) | Cold Start:65A/230VAC | ||
| Current leak | <2mA/240VAC | ||
| Protection | Overload | Larger than 105% of capacity | |
| restoration after abnormity removed | |||
| Overvoltage | |||
| Overheat | |||
| Environment | Working temp. | -20~+60℃(Refer to the tenuation curve) | |
| Working humidity | 20~90% RH, without condense | ||
| Storage temp & hmdty | -40~+80℃ | ||
| Temp. coefficient | ±0.03%/℃(0~50℃) | ||
| Vibration proof | 10~500HZ,5G 10min / cycle,X、Y、Z axes 60 min each | ||
| Safety reg. & EMC(Note.6) | Safety regulation | GB195110.1-2004/IEC61347-1:2003CE(EMC+LVD) | |
| Voltage proof | I/P-O/P:1.5KVAC | ||
| insulation resistance | I/P-O/P:100M Ohms/500VDC/25℃/70% RH | ||
| EMC irradiation | EN 55015:2006;EN61000-3-2:1995+A2:2005 | ||
| EMC disturbance proof | EN 61000-3-2:2006; | ||
| Dimensions | 287*50*30mm(L*W*H) | ||
| Packing | 0.59kg/PCS | ||
| Notes: | 1. Unless specially indicated, all data are taken under 230VAC input, rated load and 25℃environment temp. | ||
| 2.Ripple and noise: measured with a 12” double ripple cord connected in parallel with a 0.1μF and a 47 μF capacitor on 20MHz bandwidth. | |||
| 3.Accuracy: including preset errors, linear adjustment rate and load adjustment rate. | |||
| 4.Linear adjustment: taken under rated load from low voltage to high voltage. | |||
| 5.Load adjustment: taken under 0~100% of rated load. | |||
| 6. Power supply is taken as part of the whole system, and needs to be confirmed with terminal instruments for EMC. | |||